6
Function and adjustment
6.1
Logic of functions
S 01
S 02
S 04
S 19
S 09
01
RENvERSE
Each command START renverse opens-closes
Automatic reclosing.
02
COLLECTIvE uSE
The START command can open or recharge the pause
time. Recloses automatically.
03
BI-STABLE FuNCTION
Each START has the following procedure:
open-stop-close-stop-open...
It recloses automatically.
BISTABLE FuNCTION
04
wITH AUTOMATIC RECLOSING
Each START has the following procedure:
open-stop-close-stop-open...
It recloses automatically.
05
INDuSTRIAL uSE
The Partial Opening became a closes contact and the
START follow the logic of S01-S02-S03-S04
06
DEAD MAN FuNCTION
The command START open, the PARTIAL OPENING
closes. Motors stops immediatelly when the button
will be released.
01
RECLOSE wHEN THE CONTROL BOARD
wILL BE SwITCHED ON It makes a complete open and
close cycle only in cas of lack of tension the gate was open.
01
ACCESS CONTROL
When the photo-beams identify the passage, if S19 is at
"0" the pause time is 2 sec.
00
RENvERSE ON PASSAgE
Bring S04 at 1. The control unit renverse and closes.
01
SOFT-START
When the gate is opening, the speed increases