WOHLHAUPTER VarioBore 536 Mode D'emploi page 16

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
Notice:
Do not fit the serrated slides
without the coolant delivery
section. Always secure this
coupling section using the
threaded taper pin, as otherwise acci-
dents may occur due to loose pins.
Insert holder for boring and counter
weight (Fig. 5)
The insert holder ⑬ is mounted on the side
with the coolant delivery section, preset
according to the scale and then fastened
in place using the cap screw ⑭ (tightening
torque 8 Nm). The scale on the insert holder
is valid for the center slider position (= 0).
The counter weight ⑮ is set to the required
diameter according to the scale on the
opposite side and fastened.
Fig. 5
Insert holder for outside turning and
counter weight (Fig. 6)
The tool slider is moved to center position.
It must then be fed in by 1 mm in diameter
(according to display or scale).
If the internal coolant supply is used, the
21 must be removed first.
threaded pin ⃝
The outside turning insert holder is mount-
ed on the side with the coolant delivery
section, preset according to the scale
16
and then fastened in place using the cap
screw ⑭ (tightening torque 8 Nm). 0.1
mm corrections can be made using tool
adjustment.
The counter weight ⑳ is set to the required
outside turning diameter according to the
scale on the opposite side and fastened.
21
Fig. 6
Insert holder for boring and outside turn-
ing without serrated slide (Fig. 7)
For fastening purposes, the clamping bolt
⑰ is mounted with a threaded taper pin
⑤in the slider. The holder ⑱ is mounted
onto the K-profile and fastened in place
using a cap screw ⑲ with washer.
Fig. 7
Outside tuning insert holders without
serrated slide Ø 4 – 66 mm
(Ø .157" – 2.598") (Fig. 8, 9)
When fastening the outside turning insert
holder without serrated slide, note the
installation position rotated through 180°.

Publicité

Table des Matières
loading

Table des Matières