Symptom
Light bulb not working.
Food cavity not hot enough.
Food cavity too hot.
No heat, but light works.
No heat and no lights.
Troubleshooting Questions?
If you continue to have problems resolving an issue, please contact the nearest Authorized Hatco Service Agency or Hatco for
assistance. To locate the nearest Service Agency, log onto the Hatco website at www.hatcocorp.com, select the Support pull-
down menu, and click on "Find A Service Agent"; or contact the Hatco Parts and Service Team at:
Telephone: 800-558-0607 or 414-671-6350
e-mail:
support@hatcocorp.com
Halogen Bulbs
Optional halogen bulbs (Hatco P/N 02.30.081.00) can be
ordered in place of the standard incandescent display light
bulbs (120 V).
Form No. LFSTM-1019
Probable Cause
Light bulb defective.
Power turned off (O).
Temperature Control set too low.
Heating elements not working.
Temperature Control not working properly.
Excessive air movement around unit.
Unit connected to incorrect power supply.
Temperature Control set too high.
Temperature Control not working properly.
Unit connected to incorrect power supply.
Temperature Control set too low.
Heating elements not working.
Temperature Control not working properly.
Power turned off (O).
Circuit breaker tripped.

TROUBLESHOOTING GUIDE

ELECTRIC SHOCK HAZARD: Turn OFF power switch,
unplug power cord, and allow unit to cool before
performing any cleaning, adjustments, or maintenance.
Replace light bulb.
Move Power I/O (on/off) to the I (on) position.
Adjust Temperature Control to a higher setting.
Contact an Authorized Hatco Service Agent or Hatco for
assistance.
Restrict or redirect air movement (i.e., air conditioning duct
or exhaust fan) away from unit.
Contact an Authorized Hatco Service Agent or Hatco for
assistance.
Adjust Temperature Control to a lower setting.
Contact an Authorized Hatco Service Agent or Hatco for
assistance.
Adjust Temperature Control to a higher setting.
Contact an Authorized Hatco Service Agent or Hatco for
assistance.
Move Power I/O (on/off) to the I (on) position.
Reset circuit breaker. If circuit breaker continues to trip,
contact Authorized Service Agent or Hatco for assistance.