Troubleshooting Guide - Hatco FLAV-R-SAVOR PFST Série Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
WARNING
This unit must be serviced by trained and qualified
personnel only. Service by unqualified personnel may lead
to electric shock or burn.
Symptom
Display light(s) not working.
Unit operates, but is not circulating
air inside cabinet.
No heat or light.
Food cavity not hot enough.
Troubleshooting Questions?
If you continue to have problems resolving an issue, please
contact the nearest Authorized Hatco Service Agency or Hatco
for assistance. To locate the nearest Service Agency, log
onto the Hatco website at www.hatcocorp.com and click on
Find Service Agent, or contact the Hatco Parts and Service
Team at:
Telephone: 800-558-0607 or 414-671-6350
e-mail:
partsandservice@hatcocorp.com
Form No. PFSTM-0816
Probable Cause
Incandescent lamp loose or defective.
POWER ON/OFF (I/O) switch in the OFF (O)
position.
Blower motor is defective.
Incorrect voltage supplied to unit.
No power to unit.
Power
cord
connections
disconnected.
Power cord is damaged.
Defective POWER ON/OFF (I/O) switch.
Safety high-limit is tripped or open.
Incorrect voltage supplied to heating element.
Blower motor is not working.
Air heating element is defective.
TEMPERATURE Control set too low.

TROUBLESHOOTING GUIDE

ELECTRIC SHOCK HAZARD: Turn OFF power switch,
unplug power cord, and allow unit to cool before
performing any cleaning, adjustments, or maintenance.
Tighten or replace incandescent lamp. See
MAINTENANCE section for lamp P/Ns.
Move POWER ON/OFF (I/O) switch to ON (I)
position.
Contact Authorized Service Agent or Hatco for
assistance.
Contact Authorized Service Agent or Hatco for
assistance.
Check electrical receptacle and verify that power
supply matches specifications on unit. If receptacle
is not working, check circuit breaker and reset, or
plug unit into a different known working receptacle.
are
loose
or
Contact Authorized Service Agent or Hatco for
assistance.
Contact Authorized Service Agent or Hatco for
assistance.
Contact Authorized Service Agent or Hatco for
assistance.
Contact Authorized Service Agent or Hatco for
assistance.
Contact Authorized Service Agent or Hatco for
assistance.
Check blower motor—refer to Symptom "Unit
operates, but is not circulating air inside cabinet."
Contact Authorized Service Agent or Hatco for
assistance.
Adjust Temperature Control to a higher setting.
11
WARNING
Corrective Action

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Flav-r-savor pfst-1xFlav-r-savor pfst-2xFlav-r-savor pfst-1xb

Table des Matières