Vertical air flow adjustment (manually)
Air Filter
The air filter behind the inlet grille should be checked and
cleaned at least once every 2 weeks (or as necessary) to
maintain optimal performance of the air conditioner.
How to remove the air filter
1. Hold the slot under the front panel, then uplift it outwards,
and remove the front panel.
2. Pinch the handle under the air filter and make the air filter
arched, remove it from the slot from underside to upside.
3. Clean the filter with warm, soapy water. The water should be
below 40 °C to prevent distortion of the filter.
4. Rinse off and gently shake off excess water from the filter.
Allow the filter to dry before replacing it. To prevent distortion
of the filter, do not dry in direct sunlight.
Drainage
To meet different requirement of different type of air conditioner,t here a re three k inds o f m
ethods for your choice to treat the condensed water.
When cooling or heating,you can choose bottom drainage, See the following procedures to
perform bottom drainage:
1. Remove the rubber plug from the bottom of the cabinet and attach to the back drain hole (on
some models the rubber plug provided with your air conditioner accessory). For the units
without the bottom rubber plug and the back drain hole, just
install the drain tray.
2. Take out the drain tray and screws (which provided with your
air conditioner accessory).
3. Install the drain tray at the bottom of the unit and secure with
screws provided.
4. Connect the drain hose to the outlet located at one side of
the drain tray. You can purchase the drain hose or tubing
locally to satisfy your particular needs (Drain hose is not
supplied).
Suggestion: To ensure the condensed water drain off smoothly, always keep the drain oulet
of the the drain tray downward when install the drain tray.
Note: When you choice bottom drainage the air conditioner will effect cooling efficiency little
and have no voice of hit water.
13
To adjust vertical air flow direction, adjust any one of the horizontal
louvre blades. When adjusting the horizontal louver blades up or
down, always keep the top or bottom blades horizontal. This can
effectively prevent water droplets condensing on the front panel of
the unit.
DRAIN
OUTLET
DRAIN PAN
RUBBER
SCREW
PLUG