Installation of the Housing
Step 1
Remove the air conditioner from it's packaging, remove fixing
screws and slide the air conditioner out of it's housing (Refer to
Installation Steps).
Step 2
Prepare the hole in the wall so that the bottom of the housing
is well supported, the top has minimum clearance and the
air inlet louvers have clearance as shown below in options A
and B. Holes from the outside through to the cavity should be
sealed. The housing should slope down towards the rear by
about 5mm to allow water formed during operation to drain.
Step 3
Install the housing into the wall and secure. Ensure the foam
seals are not damaged. Flash, seal or fill gaps around the
inside and outside to provide satisfactory appearance and
protection against the weather, insects and rodents.
Installation of the unit into the Housing
1. Slide the unit into the housing until it is firmly against
the rear of the housing. Care is required to ensure the
foam sealing strips on the housing remain in position.
2. Connect the air conditioner to the power and position
excess cord length beneath the air conditioner base.
3. Engage the chassis fixing brackets into the bottom
housing rail and secure to the base with the screw
provided.
4. Remove the front panel from it's carton and plastic bag
and fit as per the Installation lnstruction.
5. Switch unit on. Check for operation of the unit and
check for vibration in the installation.
6. Fit the drain pan to the housing and run a drain line to a suitable location if required.
Installations of the unit into the wall
AIR IN
OPTION A
15
AIR IN
AIR IN
AIR OUT
100mm minimum
STURDY TIMBER
FRAME
TIMBER FRAMED
WALL OR PARTITION
45˚ BRICK CUT AWAY TO
CLEAR LOUVRES
BRICK
WALL
TOP
AIR IN
VIEW
LOUVRE
AIR OUT
OPTION B
NOTE: UNIT MAY BE SUPPORTED BY A SOLID
FRAME FROM BELOW OR BY A HANGER
FROM A SOLID OVERHEAD SUPPORT.
FLASH OR SEAL AROUND EXTERNAL
WALL FRAME OR ARCHITRAVE
STURDY TIMBER
EXTERNAL SUPPORT FRAME
FRAME ALL
AT BALANCE POINT OF A/C
ROUND UNIT
ALTERNATIVELY, BRACKETS
AS ILLUSTRATED BELOW
TIMBER FRAMED
WALL OR PARTITION
MAY BE USED.
Preferred method of installation into a timber
framed wall, partition or window.
FLASH OR SEAL AROUND EXTERNAL WALL
FRAME OR ARCHITRAVE
ENSURE LOUVRES ARE
ENTIRELY OUTSIDE THE
WALL
DRAIN PAN
STEADYING BRACKET
(ONE PER SIDE)
SOLID TIMBER SUPPORT
Alternative method of installation if external
support cannot be provided.
45˚ BRICK CUT AWAY TO
CLEAR LOUVRES
FRONT
BRICK
WALL
100mm
AIR IN
100mm
DRAIN PAN