External Mixer option FSE-B21 extended
The permissible setting range of parameter HARMONIC NUMBER under BAND LOCK OFF was
increased from 40 to 62.
New Application Firmware FSE-K20/21, EDGE Mobile Tests and EDGE Base
Station Tests.
Firmware application FSE-K20 (order no. 1106.4086.02) extends option FSE-K11 and firmware
application FSE-K21 (order no.1106.4186.02) extends option FSE-K11 by the analysis of 8-PSK
modulated EDGE signals according to the standard.
In this way, the functions of firmware applications FSE-K10 and FSE-K11 is also available for EDGE
signals.
The functions of the options are described in the following manuals:
Operating Manual EDGE Mobile Tests FSE-K20, Order No. 1106.4105.xx-01
where xx = 41
42
49
Operating Manual EDGE Base Station Tests FSE-K21, Order No. 1106.4205.xx-01
where xx = 41
42
49
New Application Firmware Extensions FSE-K30 and FSE-K31 for Operating
Modes GSM and EDGE Mobile and Base Station Tests
FW extension FSE-K30/FSE-K31 provides measurements in the new 850 MHz GSM band for firmware
applications FSE-K10/FSE-K20 or FSE-K11/FSE-K21.
Extended Functionality for Vector Analyzer Operating Mode (Option FSE-B7)
Adaptation for EDGE - measurement with receiver filter
The EDGE measurement with a receiver filter and the EVM calculation are performed according to
SMG2 829/99
ETSI-TDOC
measurement modes. Since it is a lowpass filter intersymbol-interference-free (ISI-free) points no
longer occur in the display modes such as constellation diagram and vector diagram. In addition, the
sync sequences provided in the unit were adapted by inverting the bits.
Note: If measurements are to be performed without a receiver filter, deactivate digital standard
EDGE (eg by switching from modulation parameter, meas filter from edge_mes to egde_ref
and back to edge_mes).
1065.6000.30
(German)
(English)
(English, US letter format)
(German)
(English)
(English, US letter format)
/ ANNEX H. This specified filter is effective in all display and
B