5.5 Dismounting Performax Easy, Performax Easy Speed (slide bracket)
5.5.1 Disengage the M12 connector on the side of the anti-static bar.
5.5.2 Unscrew the adjustable screws (nr.6) from the brackets.
5.5.3 Slide the anti-static bar with the brackets of the mounting feet in the direction of the three
points (mounting method) until the stop; pull the anti-static bar off the mounting feet in a
perpendicular manner.
5.6. Connecting the anti-static bar
Warning:
- Note the warnings at the start of this chapter.
5.6.1. Connecting the anti-static bar to the Desktop power supply
- Connect the external yellow/green wire to earth.
- Connect the cable with the M12 connector from the Desktop power supply to the anti-static
bar.
- Connect the power cable.
5.6.2. Connecting the anti-static bar to the DIN rail power supply/external power supply
- Attach the wiring as shown in Figure 5.
white
brown
yellow/green or grey
black
blue
(Cable side view)
Figure 6: Wiring of the Performax Easy and Performax Easy Speed
For personal protection and to ensure proper functioning, the grey and the blue wire
must both be connected to earth.
In the Simco-Ion Desktop power supply, these connections have already been made.
Performax Easy/Performax Easy Speed_UM_9752152130_NL_D_GB_F_V3_4
white
brown
yellow/green or grey
black
blue (GND)
GB
41