Mitsubishi Electric PUHY-P-YNW-A Série Manuel D'installation page 29

Table des Matières

Publicité

Pipes A, A
, A
, A
, A
1
2
3
4
Combination unit
Unit model
Unit 1
Unit 2
EP200YNW-A
-
EP250YNW-A
-
EP300YNW-A
-
EP350YNW-A
-
EP400YNW-A
-
EP450YNW-A
-
EP500YNW-A
-
EP400YSNW-A
EP200
EP200
EP450YSNW-A
EP250
EP200
EP500YSNW-A
EP250
EP250
EP550YSNW-A
EP300
EP250
EP600YSNW-A
EP300
EP300
EP650YSNW-A
EP400
EP250
EP700YSNW-A
EP350
EP350
EP750YSNW-A
EP400
EP350
EP800YSNW-A
EP450
EP350
EP850YSNW-A
EP450
EP400
EP900YSNW-A
EP450
EP450
EP950YSNW-A
EP350
EP350
EP1000YSNW-A
EP400
EP350
EP1050YSNW-A
EP400
EP400
EP1100YSNW-A
EP400
EP350
EP1150YSNW-A
EP400
EP400
EP1200YSNW-A
EP400
EP400
EP1250YSNW-A
EP450
EP400
EP1300YSNW-A
EP450
EP450
EP1350YSNW-A
EP450
EP450
*1 Use the ø12.7 (ø1/2) pipe if the piping length from the outdoor unit to the farthest indoor unit is 90 m (295 ft) or longer.
*2 Use the ø12.7 (ø1/2) pipe if the piping length from the outdoor unit to the farthest indoor unit is 40 m (131 ft) or longer.
*3 If the combination units 1, 2, and 3 are in a different order as listed in the table, make sure to use the pipes of appropriate size for the situation.
*4 If the pipe length after the first branching point exceeds 40 m (131 ft) (≤ 90 m (295 ft)), use the one size larger liquid pipe for all pipes from indoor
units to the first branch.
*5 When the vertical separation between the indoor units is 15 m (49 ft) (≤ 30 m (98 ft)), use the one size larger liquid pipe for all pipes from the
lower indoor units to the first branch.
Pipes B,C,D
Total capacity of indoor units
140 or below
141 to 200
201 to 300
301 to 400
401 to 650
651 to 800
801 or above
Pipes a,b,c,d,e
Capacity index of indoor unit
20, 25, 32, 40, 50
63, 71, 80, 100, 125, 140
200
250
KJ79F137H01
Pipe A
Unit 3
Liquid
Gas
-
-
ø3/8
ø7/8
-
-
ø3/8 *
ø7/8
1
-
-
ø3/8 *
ø1-1/8
2
-
-
ø1/2
ø1-1/8
-
-
ø1/2
ø1-1/8
-
-
ø5/8
ø1-1/8
-
-
ø5/8
ø1-1/8
-
ø1/2
ø1-1/8
-
ø5/8
ø1-1/8
-
ø5/8
ø1-1/8
-
ø5/8
ø1-1/8
-
ø5/8
ø1-1/8
-
ø5/8
ø1-1/8
-
ø3/4
ø1-3/8
-
ø3/4
ø1-3/8
-
ø3/4
ø1-3/8
-
ø3/4
ø1-5/8
-
ø3/4
ø1-5/8
EP250
ø3/4
ø1-5/8
EP250
ø3/4
ø1-5/8
EP250
ø3/4
ø1-5/8
EP350
ø3/4
ø1-5/8
EP350
ø3/4
ø1-5/8
EP400
ø3/4
ø1-5/8
EP400
ø3/4
ø1-5/8
EP400
ø3/4
ø1-5/8
EP450
ø3/4
ø1-5/8
[mm (in)]
Pipe
Liquid
Gas
ø9.52 (ø3/8)
ø15.88 (ø5/8)
ø9.52 (ø3/8)
ø19.05 (ø3/4)
ø9.52 (ø3/8)
ø22.2 (ø7/8)
ø12.7 (ø1/2)
ø28.58 (ø1-1/8)
ø15.88 (ø5/8)
ø28.58 (ø1-1/8)
ø19.05 (ø3/4)
ø34.93 (ø1-3/8)
ø19.05 (ø3/4)
ø41.28 (ø1-5/8)
[mm (in)]
Pipe
Liquid
Gas
ø6.35 (ø1/4)
ø12.7 (ø1/2)
ø9.52 (ø3/8)
ø15.88 (ø5/8)
ø9.52 (ø3/8)
ø19.05 (ø3/4)
ø9.52 (ø3/8)
ø22.2 (ø7/8)
Pipe A
*
Pipe A
*
3
1
2
Liquid
Gas
Liquid
Gas
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ø3/8
ø7/8
ø3/8
ø7/8
ø3/8
ø7/8
ø3/8
ø7/8
ø3/8
ø7/8
ø3/8
ø7/8
ø1/2
ø1-1/8
ø3/8
ø7/8
ø1/2
ø1-1/8
ø1/2
ø1-1/8
ø1/2
ø1-1/8
ø3/8
ø7/8
ø1/2
ø1-1/8
ø1/2
ø1-1/8
ø5/8
ø1-1/8
ø1/2
ø1-1/8
ø5/8
ø1-1/8
ø1/2
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø1/2
ø1-1/8
ø1/2
ø1-1/8
ø5/8
ø1-1/8
ø1/2
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø1/2
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
GB-27
Pipe A
*
3
3
3
Liquid
Gas
Liquid
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ø3/8
ø7/8
ø3/4
ø3/8
ø7/8
ø3/4
ø3/8
ø7/8
ø3/4
ø1/2
ø1-1/8
ø3/4
ø1/2
ø1-1/8
ø3/4
ø5/8
ø1-1/8
ø3/4
ø5/8
ø1-1/8
ø3/4
ø5/8
ø1-1/8
ø3/4
ø5/8
ø1-1/8
ø3/4
[in]
Pipe A
4
Gas
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ø1-3/8
ø1-3/8
ø1-3/8
ø1-3/8
ø1-3/8
ø1-3/8
ø1-3/8
ø1-3/8
ø1-3/8

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Puhy-p-ynw-a-bs sériePuhy-ep-ynw-a sériePuhy-ep-ynw-a-bs sériePuhy-p200ynw-aPuhy-p250ynw-aPuhy-p300ynw-a ... Afficher tout

Table des Matières