6.4 Putting into Operation
Turn the welding fumes filter on using the switch marked with "0" and "I" symbols
●
(see Pic. 12, pos. 18) ("I
Check on the coasting fan now whether the direction of impeller rotation is
●
identical with the direction of the arrow on the fan body. The impeller must turn in
the direction towards the blowing opening.
If the impeller turns in incorrect direction, it is necessary to exchange two phase
●
conductors in the motor terminal box (see Pic. 13, pos. 19)
The unit can be turned on/off always using the switch on the Control Box
●
(see Pic. 12, pos. 18).
The green signal LED (see Pic. 12, pos. 17) indicates that the unit is in operation.
●
Carry out welding only if this green LED is lit up.
The Control Box is also used for housing of the electric components of provided
●
optional auxiliary equipment.
Order No.: 150 0004
Technical changes and errors reserved.
) and turn it off again immediately.
"
Picture 12, Controls on the Control Box
Picture 13, Terminal box on the motor
KEMPER Welding Fumes Stationary Filter
- 70 -
Instruction Manual - EN
rev.:
0
Status as of: 04/2014