11
Technical data
Optical data (typ.)
Scanning distance (from reference point)
Scanning distance tolerance
Size of light spot
Scanning range with reflective foil RF10 C
Type of light
Max. ambient light
Colour / intensity tolerance
Electrical data (typ.)
Operating voltage U
B
Residual ripple within U
B
Power consumption I
no load
O
Switching output Q
Output current I
e
Voltage drop U
d
Switching frequency (ti/tp 1:1)
Max. capacitive load
Time level for Q
KL / TR input
When trigger input is set
- Blanked out (triggered) mode
- Unsolicited mode
- Min. response time
When key lock is set
- Keys are locked
- Keys are free
IN ET input (Extern teach mode)
Teach in > 3 s (time lock)
Normal mode
Min. response time
IN ES input (Extern scan mode)
Scan > 3 s (time lock)
Operating mode
Min. response time
Serial interface
Protective circuits
VDE protection class
60
FT 50 C-1-S1-L8
FT 50 C-2-S1-L8
12 ... 32 mm
15 ... 30 mm
± 6 mm (with Tol C
± 5 mm (with Tol C 3
3 and Tol I 2)
and Tol I 2)
Ø 4 mm with scan-
2x2 mm
ning distance 22 mm
ning distance 22 mm
application-specific
white light (pulsed)
EN 60947-5-2
adjustable (4 levels each)
12 ... 28 V DC
10 %
≤ 40 mA
PNP or NPN, N.O./ N.C. reversible
≤ 100 mA
≤ 2.4 V
max. 500 Hz
< 100 nF
50 ms drop-out delay time adjustable
Input key lock or triggering (adjustable)
PNP / NPN
when > 12 V ... 28 V
when < 3 V or open
10 ms
PNP / NPN
when > 12 V ... 28 V
when < 3 V or open
PNP / NPN
> 12 V ... 28 V
< 3 V or open
2 ms
PNP / NPN
> 12 V ... 28 V
when < 3 V or open
2 ms
RS485 (half-duplex), 1 stop bit, no parity, baud rate selectable via
telegram and Progsensor software (factory setting 19200 Baud)
Reverse battery protection, short circuit protection (not RS485)
FT 50 C...S1 Colour sensor - GB - 068-13821 - 10.10.2011-04
Mounting and
operating instructions
FT 50 C-3-S1-L8
18 ... 22 mm
± 2 mm (with Tol C 3
and Tol I 2)
with scan-
5x1 mm
with scan-
2
2
ning distance 22 mm