Mounting and
operating instructions
Example telegram
(In the example, the sensor has the address 1, a teach-in process is carried out without altering the tolerance)
Master telegram „Start teach colour"
Master telegram
Designation
1st byte
Address
2nd byte
Length
3rd byte
Command
4th byte
Start „teach colour"
5th byte
Check sum
Master telegram „End teach colour"
Master telegram
Designation
1st byte
Address
2nd byte
Length
3rd byte
Command
4th byte
Function
5th byte
Check sum
8.5.12
Set tolerance
Command (byte 3): decimal 73; hexadecimal 0x49
Parameter:
bit 0.1: colour tolerance level 1 to 4 (binary coded 0 to 3)
bit 2.3: intensity tolerance level 1 to 4 (binary coded 0 to 3)
Parameter format:
7 bit data byte
Reply (byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
The sensor adopts the tolerances according to the parameter values.
INFORMATION
This command is only to be used in conjunction with a teach colour process (see 8.5.11). The
tolerance programmed with this command is used as a preselection for all following teach-in
processes.
FT 50 C...S1 Colour sensor - GB - 068-13821 - 10.10.2011-04
Sensor's reply telegram
Decimal Hex.:
129
81
1st byte
5
05
2nd byte
88
58
3rd byte
1
01
4th byte
93
5D
Sensor's reply telegram
Decimal Hex.:
129
81
1st byte
5
05
2nd byte
88
58
3rd byte
0
00
4th byte
92
5C
Designation
Decimal Hex.:
Address
129
Length
4
Reply
89
Check sum
92
Designation
Decimal Hex.:
Address
129
Length
4
Reply
89
Check sum
92
81
04
59
5C
81
04
59
5C
57