206_TRI-SEN – Functions
It is recommended to measure the lower, middle and upper solar
cells because of the temperature difference between the upper
and lower solar cells. The average temperature reading is stored
until the device is switched off.
Warning: switching the tRi-sen off will delete all measured data!

9.3 Measuring the irradiation

Once the TRI-SEN is switched on, the integrated solar cells meas-
ure the irradiation. After the temperature measurement, the
TRI-SEN is placed in the mounting which is fitted flush with the
modules (chapter 4.5). The position of the TRI-SEN at module level
is crucial for the accuracy and reliability of the STC evaluation!
The irradiation is measured continuously, stored at intervals in the
memory and transferred to the TRI-KA. The current irradiation is
shown in the top left-hand corner of the screen.

9.4 Measuring the angle of inclination

Once switched on, the TRI-SEN continuously measures the angle
of inclination, shown in the top right-hand corner of the screen.
For a reliable measuring result, the TRI-SEN should be placed in
the mounting fitted to the module frame (chapter 4.5).

Transfer of measuring data_207

10. tRansFeR oF MeasuRing data

10.1 transfer of tRi-sen data to the tRi-Ka

The data measured by the TRI-SEN are wirelessly transferred to
the TRI-KA. A wireless connection is automatically established
once both instruments are switched on. The connection is shown
at the top of the screen (picture).
If the wireless connection is disrupted, the data are stored in the
TRI-SEN until they are synchronised. This allows measurement
even without a connection. The disruption of the data connection
is signalled by a message popping up on the TRI-KA screen.
The TRI-SEN should not be switched off before the data have
been transferred, as otherwise all values will be lost and the meas-
urement is no longer reliable.

10.2 transfer of tRi-Ka values to the pc

Once saved, all measured values are automatically stored on the
SD card of the TRI-KA.
The data are uploaded using the TRI-KA PC software and insert-
ing the memory card into the computer or the supplied reader.
More details on how to upload the data are provided in the soft-
ware manual on the SD card.
the software is saved on the sd card of the tRi-Ka in the
directory "...\tRi-Ka\update"; it can also be downloaded at
www.tritec-energy.com.