202_TRI-KA – Functions
set irradiation tolerance (%)
Maximum permitted variation in irradiation (as a percentage)
during measurement of the characteristic curve. If the irradiation
exceeds the tolerance value, the measurement is aborted result-
ing in an error message.
device information and firmware update
Press the Info button to check the serial number, the software ver-
sion, the battery status and the date of calibration of the TRI-KA
and TRI-SEN.
If the Firmware Update button is highlighted in yellow, a new
firmware version for the TRI-KA is available on the SD card. Click
the button to install the new firmware.
Use the TRI-SEN / TRI-KA buttons to change between TRI-SEN and
TRI-KA data. Click the gear button to return to the Settings menu.
8. tRi-sen – oVeRVieW
8.1 case and control elements
1. Button to measure the temperature
2. Display to read the current and measured values
1
3. Polycrystalline cell for irradiation measurement
4. Monocrystalline cell for irradiation measurement
2
5. Power button to switch the TRI-SEN on and off
6. Temperature sensor
7. Plug-in point for the charger cable
3
4
5
6
7
TRI-KA – Functions_203