7.5.
label
Example:
Body material
Seal material
Orifice
Circuit function
Type
6606 T 1,6 FKM PD
G1/8
24V
00450000
Identification number
Voltage/frequency output
Nominal connection pressure
english
16
8.
insTallaTiOn
8.1.
safety instructions
Danger!
Risk of injury from high pressure in the equipment!
Before loosening the lines and valves, turn off the
pressure and vent the lines.
Risk of injury due to electrical shock!
Before reaching into the device or the equipment,
switch off the power supply and secure to prevent
reactivation!
Observe applicable accident prevention and safety
regulations for electrical equipment!
Warning!
Risk of injury from improper installation!
Installation may be carried out by authorized technicians
only and with the appropriate tools!
Risk of injury from unintentional activation of the
system and an uncontrolled restart!
Secure system from unintentional activation.
Following installation, ensure a controlled restart.
english
18
PNVAK 2 bar
DC
3.4W
CE
W14UN
7.6.

electrical data

Connections:
Spade connection in accordance
with DIN 43650 C for cable plug
Type 2506 on top or on side
Rectangular plug for Type 2505
2 FEP flying leads, AWG24,
500 mm long
Power supply:
12 V DC
24 V DC
110 – 120 V UC
230 – 240 V UC
Voltage tolerance
±10 % - Residual ripple 10 %
Nominal output
12 – 24 V
3.4 W
110 – 240 V
4.0 W
Nominal
operating mode
100 % continuous operation
for block installation
if temperatures of media or
surrounding area above +40 °C:
Intermittent duty 40 % (10 min)
Note the information specified on the label for
voltage, type of current, and pressure.

8.2. fluid installation

Danger!
Risk of injury from high pressure in the equipment!
Before loosening the lines and valves, turn off the
pressure and vent the lines.
Installation position:
any, actuator preferably upwards.
Installation
Before installation, clean any possible dirt off the pipe-
lines and flange connections.
If required, install a dirt trap to prevent malfunctions.
Pay attention to the flow direction of the valve.
Type 6126 / 6606
english
17
17
Mesh size:
5 µm