Transporting And Storing The Generating Set; Repairing Minor Faults - SDMO KOHLER HX3000C Manuel D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1

6 Transporting and storing the generating set

6.1
Transport and handling conditions
Before transporting the unit, check that the bolts are correctly tightened, close the fuel tap (if fitted) and disconnect the starter
battery (if fitted). The unit should be transported in its normal operating position; never lay it on its side. The unit should be handled
gently and brusque movements should be avoided. Ensure that the place where it is to be stored or used is carefully prepared
beforehand.
6.2
Storage conditions
This procedure for storing the unit or protecting it over the winter must be respected if it is not used for a period of up to 1 year. For
longer periods of storage, it is recommended to contact your nearest agent or to start up the unit for a few hours every year,
ensuring that the storage procedure is respected afterwards.
Drain the fuel and change the engine oil:
1.
Start the unit and allow it to operate until it runs out of fuel.
2.
Set the switch to OFF (A5).
3.
Clean the sediment bowl (A10-C2).
4.
Close the fuel tap (A4).
5.
Top up the oil.
Grease the cylinder and valves:
6.
Remove the spark plug (A12-F2) then, via its aperture, pour in approx. one teaspoon of new engine oil.
7.
Refit a new spark plug in its place.
8.
Pull the starter-recoil reel handle (A7) several times to distribute the oil inside the cylinder.
Storing the unit:
9.
Clean the unit and cover it with a protective cover.
10. Store it in its normal position, in a clean, dry and well ventilated area.

7 Repairing minor faults

The unit...
Does not start
Stops
Does not function normally
(noise, smoke, etc.)
Does not supply electrical
current
Check that:
The checks before starting have been
performed.
YES
The start-up procedure has been
followed correctly.
YES
The equipment to be used has not
been connected prior to starting.
YES
The spark plug is in good condition and
correctly connected.
YES
The oil level is correct.
YES
The fuel level is correct.
YES
The air filter is in good condition.
YES
Maintenance has been correctly
performed on the unit components.
YES
Have the unit checked by one of our
agents*.
The circuit breaker(s) has/have been
tripped.
YES
The connected equipment and their
power cords are not faulty.
YES
Have the unit checked by one of our
agents*.
Solutions to be applied:
Perform the necessary checks.
NO
Re-read the start-up procedure and repeat
the start-up attempt.
NO
Disconnect the equipment then try to start
NO
the unit again.
Replace the spark plug (330830005).
NO
Top up with oil.
NO
Fill up with fuel.
NO
Clean the air filter.
NO
Perform maintenance on the unit as per
NO
the recommendations.
Check the capacity of the unit and press
the circuit breakers.
NO
Try with another item of equipment and
another power cord.
NO
*France: 0.806.800.107 (call charge).

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Kohler hx4000cKohler hx6000cKohler hx7500tc

Table des Matières