OPERATING CONTROLS

51.
Charged battery warning light
When all yellow LEDs are on, the batteries are charged.
Residual autonomy depends on battery capacity and
working conditions.
When the red LED is on, batteries are discharged. The
autonomy is over, the batteries must be recharged (see
the procedure in the relevant paragraph).
52.
Side broom lever
(Forward) side broom lowered
(Backward) side broom lifted
53.
Main broom lever
(Forward) main broom lowered
(Backward) main broom lifted
54.
Hopper lever
(Forward) hopper lowered
(Backward) hopper lifted
55.
Hopper dumping door lever
(Forward) dumping door opened
(Backward) dumping door closed
51
55
54
53
56
5
2
63
SR 1601 B
56.
Hour counter
57.
Ignition key:
When turned to "O", it turns the electrical system off
and disables all machine functions.
When turned to "I" it enables the machines functions.
When turned to "II" it starts the main motor.
As soon as the main motor starts, release the key,
which returns to "I".
58.
Horn switch
59.
Vacuum fan/fi lter shaker switch
(Lower position) fi lter shaker activation
(Upper position) vacuum fan and dust guard system
activation
60.
Dust guard system switch (optional)
61.
Working light switch (optional)
62.
Steering wheel adjustment lever (optional, equipped on SR
1601 MAXI)
63.
Hopper overtemperature warning light
64.
Clogged hopper fi lter warning light