Operating Controls - Nilfisk SR 1601 Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH

OPERATING CONTROLS

51. Charged battery warning light:
When all yellow LEDs are on, the batteries are charged.
Residual autonomy depends on battery capacity and
working conditions.
When the red LED is on, batteries are discharged. The
autonomy is over, the batteries must be recharged (see
the procedure in the relevant paragraph).
52. Side broom lever:
("forward" position) side broom lowered
("backward" position) side broom lifted
53. Main broom lever:
("forward" position) main broom lowered
("backward" position) main broom lifted
54. Hopper lever:
("forward" position) hopper lowered
("backward" position) hopper lifted
55. Hopper dumping door lever:
("forward" position) dumping door opened
("backward" position) dumping door closed
55
54
53
52
10
INSTRUCTIONS FOR USE
51
56
57
63
SR 1601 - 33019318
56. Hour counter
57. Ignition key:
When turned to "O", it turns the electrical system off
and disables all machine functions.
When turned to "I", it enables the machines functions
When turned to "II" it starts the main motor.
As soon as the main motor starts, release the key,
which returns to "I".
58. Horn switch
59. Vacuum fan / filter shaker switch:
(lower position) filter shaker activation
(upper position) vacuum fan and dust guard system
activation
60. DustGuard™ system push-button (optional)
61. Working light switch (optional)
62. Steering wheel adjustment lever (optional)
63. Hopper overtemperature warning light
64. Clogged hopper filter warning light
58
59
60
64
revised 08/2018
61
62
P100336
01/2009

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1330010313300149

Table des Matières