Installation Procedure - Franke FHCL 604 3G TC Manuel D'installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29
FHCL 604 3G TC / FHCL 755 4G TC / FHTL 604 3G TC / FHTL 604 4G / FHTL 755 4G TC
20 mm

Installation procedure

The appliance is fixed to the unit by means of
the brackets and accessories provided.
Make sure that there is free access to the
fixing elements in front and in the rear
after the installation of the appliance.
Prepare the hole in the worktop according
to the dimensions indicated. Be sure to
comply with the dimensions indicated.
Yp
Xtop
Htop
Model
xp mm yp mm xtop
FHCL 604 3G TC 590
FHCL 755 4G TC 750
FHTL 604 3G TC
590
FHTL 604 4G
590
FHTL 755 4G TC
750
Xp
Ytop
ytop
htop
mm
mm
mm
510
550
480
40
510
550
480
40
510
550
480
40
510
550
480
40
510
550
480
40
Apply the sealing strip around he hole and
position the hob.
Fix the appliance with the screws and
brackets.
Remove any excess sealing strip.
Connection to gas supply
Connect the appliance to the gas supply in
compliance with the current regulations,
only after making sure it is arranged for the
type of gas to be used. Otherwise, carry out
the operations described in the paragraph
„Replacing injectors".
For liquid gas use pressure regulators
complying with the current regulations.
Connection to the gas supply can be made
in two ways:
A. Connect the gas hob using a 12 mm
diameter rigid copper pipe (3). To ensure
a good seal, use the elastomer gasket
supplied as an accessory (1).
B. Connect the hob using a continuous-
surface flexible steel tube (2). Also in this
case, to ensure a good seal use the gasket
supplied as an accessory (1). The maximum
length of the hose is 2 linear metres.
IMPORTANT: if a stainless steel hose is used, it
must be installed so as not to touch any mobile
part of the furniture. It must pass through an
area where there are no obstructions and where
it is possible to inspect it on all its length.
After connection to the gas supply light up
the burners and turn the knobs from max
position to minimum position to check
flame stability.
After carrying out the connection use soapy
water to check for any leaks.
– 9 –
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Fhcl 755 4g tcFhtl 604 3g tcFhtl 604 4gFhtl 755 4g tc

Table des Matières