Technical Data; Specified Conditions Of Use; Residual Risks - Güde GAKS 350 E Traduction Du Mode D'emploi D'origine

Table des Matières

Publicité

EnGlISH
22

Technical Data

Electric chain saw
Art. No ...............................................................................95167
supply .........................................................230 V~50Hz
Rated input P1.....................................................900 W
bar length .........................................................350 mm
Cutting length ............................................................235 mm
Chain speed ........................................................15 m/s
Chain oil tank capacity ................................... 100 ml
Protection class .............................................................II
Weight ........................................................................5 kg
warning: The vibration emission level will vary because of the ways in which a power tool can be used and may
increase above the level given in this information sheet.
The vibration emission level may be used to compare one tool with another.
It may be used for a preliminary assessment of exposure.
An accurate estimate of the vibratory load should also take into account the times when the tool is shut down
or when it is running but not actually in use. This may significantly reduce the vibratory load over the total
working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the
tool and the accessories, keep the hands warm, organisation of work patterns.
the safety measures stated in the service manual. Act
responsibly toward third parties.
In case of any doubts about connection and
operation refer please to our customer center

Specified Conditions of Use

Respecting technical data and safety precautions.
Do not use this product in any other way as stated
for normal use. Not observing general regulations
in force and instructions from this manual does not
make the manufacturer liable for damages.
requirements for operating staff 
The operating staff must carefully read the Opera-
ting Instructions before using the appliance.
Qualification:  Apart from the detailed instructions
by a professional, no special qualification is necessary
for appliance using.
minimum age:  Persons over 18 years of age can
only work on the appliance. An exception includes
youngsters trained in order to reach knowledge
under supervision of the trainer during occupational
education.
GaKS 350 E
Read and understand the
operating instructions before
using the appliance. Abide by all
noise and Vibration Information
Sound power level L
.........................................108 db (A)
WA
Sound pressure level L
..................................85,8 db (A)
1)
pA
wear ear protectors!
Vibration emission value a
h
Measured according to 2000/14/EG + 2005/88/EG,
1)
Uncertainty K =3 db (A)
Measured according to EN 60745, Uncertainty K=1,5
2)
m/s
2
Training:  Using the appliance only requires corre-
sponding training by a professional or the Operating
Instructions. No special training is necessary.
The operator is responsible for accidents or risks to
third parties.
Observe to keep out of dangerous zone

residual risks

Danger of injury !
Contact with the saw chain can cause casualties.
Never touch moving chain by hands.
Danger of kickback !
Kickback can lead to casualties.
Danger of burns !
Chain and guiding groove warm up in operation.
GAKS 350 E
.................................6,5 m/s
2)
2