Setting the parameters
You can reach "Setting the parameters" in the main
menu by placing the selection bar on it by means of
the "arrow" keys and then pressing the "Enter" key.
The letters A and B in the left and right upper corner
of the upper bar indicate that 2 induction electrodes
have been connected. If only 1 electrode had been
connected, only the letter A or B would be shown.
In the middle section of the screen you find the set
parameters. You can adjust the desired parameters by
means of the central control. With the 4 "arrow" keys,
you can go to the various parameters and finally to the
lower bar. If no Circuplode had been connected, the
left and right column of this middle section will remain
blanc.
If an electrode is insufficiently loaded during treat-
ment, this is indicated by the fact that the cursor bar
will light up and a beep will be heard. No power is
applied until the loading is correct. A minimum "de-
tector" power is used for measuring the load.
Below right is the number of the memory place. How
you store a program, is described hereunder.
The presented parameters can be changed by first
going to the parameter section with the "arrow up"
key. There you can go to each parameter by means
of the "arrow" keys and you can change them by
turning the central control.
The frequency of 800 Hz can only be set if only one
Circuplode-E is connected.
Should a 100 W Circuplode be connected and should
the peak power be set to 200 W, the Curapuls 670
will automatically reduce the peak power to 100 W
as soon as the treatment is started.
The intensity can be set in 5 Watt divisions.
The time can be set per 30 seconds, with a maxi-
mum of 30 minutes.
If you go to the "<<" sign in the lower left corner by
means of the "arrow left" key and press the Enter
key, you return to the main menu.
Storing a program
If you wish to store the program after you have changed
the parameter settings, go to the "store" symbol in the
lower right corner by means of the "arrow" keys. With
the central control you can choose the desired number
for storage. A "*" behind a number means that a pro-
gram has already been stored under this number. If
you push the Enter key, the already stored program
will be overwritten, without furter warning.
To clear a memory place number, you put all setting
to their minimal values (65 µs, 26 Hz, 0W and 0 min.)
and you store these settings in the desired memory
place.
With the "arrow down" key you go back to the main
menu, from where you can proceed to the treatment
memory or the treatment protocols. Push the Enter
key.
Treatment memory
You choose a program number by turning the cen-
tral control.
Only the numbers of the memory places where a
program has been stored are shown. There is a dif-
ferentiation between conventional mode and mean
power. Should you, for example, have programmed
24 programs for conventional mode and 1 for mean
power mode, you only get to see one program
number when you wish to call a program for mean
power.
Also the parameters of already stored programs can
be changed and re-stored.
If you change a parameter, the text in the upper bar
changes in "Treatment parameters" and next to the
protocol number the "store" symbol appears, with
behind it a number.
You can overwrite the present program (go with the
"arrow" keys to the most right "store" symbol and
push the Enter key) or assign a new memory place
number (first choose a new number with the central
control and then push the Enter key).
Treatment protocols
By means of the "arrow down" key or the central
control you can choose from;
• Arthralgies
• Neuralgies
• Dermatology
• Vasomotoric insufficiency
• Insertion tenopathies
• Myalgies
• Soft tissue lesions
For an overview of the protocols, we refer to the
appendix.
If you wish to go back to the protocol screen, you
can press the "arrow left" key at any time.