Technical Data - Migatronic RALLY MIG 161i Guide De L'utilisateur

Masquer les pouces Voir aussi pour RALLY MIG 161i:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21

Technical data

Power source
Mains voltage *)  ±15% (50Hz-60Hz), V
Minimum generator size, kVA
Fuse, A
Mains current effective, A
Mains current max., A
Power (100%), kVA
Power max., kVA
Open circuit power, W
Efficiency, %
Power faktor
Current range, A
Duty cycle, 100% at 20°C, A
Duty cycle, 60% at 20°C, A
Duty cycle, max. at 20°C, A/%
Duty cycle, 100% at 40°C, A/V
Duty cycle, 60% at 40°C, A/V
Duty cycle, max. at 40°C, A/%/V
Open circuit voltage, V
Sphere of application
1)
Protection class
2)
Norm
Dimensions (HxWxL), mm
Weight, kg
90
80
70
60
50
40
30
20
10
0
0
40
*) The machine enables down to -30% by reducing the max. amperage
1) S This machine meets the demand made for machines which are to operate in areas with increased hazard of electric chocks
2) The machine is designed for indoor and outdoor use according to protection class IP23S. The machine may be stored but is not intended to be used outside
during precipitation unless sheltered.
RALLYMIG 161i
1x230
6.5
16
13.0
22.9
2.4
4.4
30
80
0.99
20-160
135
145
160/40
100/24.0
115/24.6
160/25/26.4
90
S/CE/CCC
IP23S
EN/IEC60974-1.
EN/IEC60974-5.
EN/IEC60974-10
370x230x450
13
Static Characteristic
80
120
160
EC DECLARATION OF CONFORMITY
hereby declare that our machine as stated below
Type: RALLYMIG 161i
conforms to directives: 2014/35/EU
European standards:
Regulation:
Issued in Fjerritslev 10.02.2021
RallyMig 161i
MIG Load line
MMA Load line
I2 [A]
13
MIGATRONIC A/S
Aggersundvej 33
9690 Fjerritslev
Denmark
2014/30/EU
2011/65/EU
EN IEC60974-1:2018/A1:2019
EN IEC60974-5:2019
EN / IEC60974-10:2014/A1:2015
2019/1784/EU
Kristian M. Madsen
CEO

Publicité

Table des Matières
loading

Table des Matières