Instructions for use for the user

10.14. Deactivating the operating unit

● Press the ON/OFF button 2 for one second.
► LEDs 5, 7 and 9 and the LED wheels c and f go out.
► The operation LED 1 lights up in red.
► The operating unit is in standby mode.

10.15. Cancelling the post-drying programme

after the combi-mode, the post-drying programme is started automatically. This in-
volves heating the sauna room to 80 °C with the fan running for 30 minutes.
The post-drying programme also keeps running if the operating unit is deactivated.
To install the bench sensor, perform the following steps:
1. Press the ON/OFF button 2 for one second.
► The operating unit is activated.
► The operation LED 1 lights up in red.
2. Press the ON/OFF button 2 again for one second.
► The operating unit is activated.
► The post-drying programme was cancelled.
► The operation LED 1 lights up in blue.

10.16. Switching off the power unit

If you will not be using the sauna control unit for an extended period of time,
switch the sauna control unit off at the power unit.
● Press the ON/OFF button A.
► The operation LED 1 goes out.
► The sauna control unit is switched off.