Installation instructions, only for experts
8.6. Status output
The function selection switch 7 can be used to help to decide whether the status
output should be activated when the sauna is operating or during the post-drying
programme. Activation during the post-drying programme allows the evapora-
tor to be drained automatically when a combi heater with an auto refill function
is being used.
● The function selection switch 7 is set to the OFF position as standard. This ac-
tivates the status output during sauna operation.
● If you wish to activate the status output for the post-drying mode, place the
function selection switch 7 in the ON position.
8.7. Setting the operating mode for the additional output
The additional output can either be dimmed or switched on and off. The dimmer
switch function is activated or deactivated using the function selection switch 8.
● The function selection switch 8 is set to the ON position as standard. This ac-
tivates the dimmer switch function.
● If you wish to deactivate the dimmer switch for the additional output, place
the function selection switch 8 in the OFF position.
p. 29/46
EN