Instructions for installation and use
Fan
Contact rating:
Fuse:
Setting ranges
Temperature (sauna mode):
Temperature (combi mode):
Humidity:
The maximum humidity level which can be set depends on the temperature
of the sauna. The higher the sauna temperature, the lower the maximum
humidity level which can be set.
Thermal safety
Heater sensor with excess temperature fuse (139 °C shut-off temperature)
Automatic heating time limitation 6 h*
Single-sensor mode or two-sensor mode for selection
Connection cables
Power supply cable:
Heater supply cable (temperature-resistant
up to 150 °C):
Sensor wires (temperature-resistant up to 150 °C):
Light wire:
Fan wire:
* EN 60335-2-53 specifies a heating time limitation of 6 h for saunas for private use.
p. 46/46
100 W
1A T
55 °C to 110 °C
20 °C to 75 °C
25% to 80%
min. 5 x 2.5 mm²
min 2.5 mm²
min 0.5 mm²
min. 1.5 mm²
min. 1.5 mm²