13.2. Low-water display

The sauna control unit features an automatic low-water shut-off function in combi
mode as far as your combi heater supports this function.
If the water tank in the evaporator is empty, this is indicated by a recurring warn-
ing tone emitted by the power unit and by the flashing lights in the humidity LED
wheel c. The evaporator switches off.
● Pour water into the water tank in the evaporator.
► After a short period, the warning LEDs go out and the evaporator starts
heating up again.

13.3. Fuses

Fuses for light, fan/power expansion and electronics as well as a spare fuse are
located in the sauna control unit's connection area.
These are 1A time delay micro fuses and can be ordered using the PRO-FUSE
item number.
Light
Electronics
In order to replace the fuse, pull the fuse link straight out and insert the new fuse.
Fan/power expansion
p. 44/46