5/3 way valve:
in middle position, all outlet ports closed
5/3 way valve:
in middle position, Outlet Ports 2 and 4 vented, Pressure Inlet 1 closed
Media
• filtered compressed air (max. particle size 10 µm), preferably non-oiled
• operation is possible with oiled air
• seal materials:
• permissible medium temperature:
• permissible ambient temperature:
• operational pressure range:
The pilot pressure of the pneumatic controller is dependent on the pressure of the flow
NOTE
of medium: it must not exceed a maximum of 8 bar!
ATTENTION!
Observe the permissible pressure range given on the rating plate!
Pressure difference between Ports 1 and 3/5 ≥ ≥ ≥ ≥ ≥ 2 bar
Electrical connections
• read the voltage, electrical power, type of protection and current from the rating plate!
• voltage tolerance ±10%
• electrical connection: Instrument socket type 2506 to the tag connection on the coil (tightening
torque: 1 Nm)
• protection level IP 65 (only in combination with appliance socket type 2506)
• to match the cable run, the instrument socket can be mounted rotated by 180°
• refer to types 6106 or 8640 for other connection possibilities
ATTENTION!
When screwing down the instrument socket onto the coil,
ensure that the flat seal is well seated!
BP = NBR and polyurethane for 3/2 and 5/2 valves
BB = NBR and POM for 5/2 pulse and 5/3 valves
max. +50° C
max. +55° C
2 - 8 bar
T
D
ECHNICAL
ESCRIPTION
6516 / 6517 - 9