Installation
f Pull the cable grommets into the back panel, until both lock-
f
ing tabs engage.
19
3 Nm
f Fit the pipes with flat gaskets onto the water connections.
f
f Open the 3-way ball shut-off valve or the shut-off valve in the
f
cold water supply line.
Making the electrical connection
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
The connection to the power supply must be in the form
of a permanent connection in conjunction with the re-
movable cable grommet. Ensure the appliance can be
separated from the power supply by an isolator that dis-
connects all poles with at least 3 mm contact separation.
86
|DHE Connect | DHE Touch   
24
5 Nm
WARNING Electrocution
Ensure that the appliance is earthed.
Material losses
!
Observe the type plate. The specified rated voltage must
match the mains voltage.
f Connect the power cable to the mains terminal.
f
Fitting the lower back panel section
f Fit the lower back panel section into the back panel. Check
f
that both locking tabs are engaged.
f Align the mounted appliance by undoing the fixing toggle,
f
aligning the power supply and back panel, and then re-tight-
ening the fixing toggle. If the back panel does not sit flush
against the wall, you can secure the appliance at the bottom
with an additional screw.