INSTALLATION
Appliance shutdown
f Then press the button repeatedly until the desired connected
f
load appears on the display. The connected load selected is
adopted immediately.
11.1.2 Mini wireless remote control
The mini wireless remote control is factory registered to the de-
vice. If no data transmission takes place during commissioning,
repeat the learning process (see chapter "Installation options /
Registering the mini wireless remote control".
11.1.3 Appliance handover
f Explain the appliance function to users and familiarise them
f
with its operation.
f Make the user aware of potential dangers, especially the risk
f
of scalding.
f Hand over the instructions.
f
www.stiebel-eltron.com
11.2 Recommissioning
Material losses
!
To ensure that the bare wire heating system is not dam-
aged following an interruption to the water supply, the
appliance must be restarted taking the following steps.
f Isolate the appliance from the power supply; do this
f
by switching off the fuses or switching the device to
OFF.
f Open the tap for a minimum of one minute until the
f
appliance and its upstream cold water inlet line are
free of air.
f Switch the power supply back on, or set a tempera-
f
ture on the device or wireless remote control.
12. Appliance shutdown
f Isolate all poles of the appliance from the power supply.
f
f Drain the appliance (see chapter "Installation / Maintenance /
f
Draining the appliance").
DHE Connect | DHE Touch |