INSTALLATION
Installation options
The appliance is equipped with an anti-scalding protection func-
tion, which the qualified contractor can set if required. To do this,
the appliance must be opened.
Anti-scalding protection activation
f Press the "Service" button on the PCB in the appliance.
f
1
1 "Service" button on the appliance
The "Internal anti-scalding protection" (in "Settings / Service"
menu) is visible for 5 minutes.
f Set the anti-scalding protection temperature.
f
f Tap on "Active" and then the tick symbol to enable the an-
f
ti-scalding protection.
Setting ranges:
- Setting range 20 - 85 °C
- Recommended setting 43 °C
92
|DHE Connect | DHE Touch   
Anti-scalding protection deactivation
f Proceed as described under "Anti-scalding protection acti-
f
vation". Deactivate anti-scalding protection by tapping the
"Active" tick symbol (deactivate).
13.6 Water installation on finished walls
Note
This type of connection changes the IP rating of the ap-
pliance.
f Change the type plate. Cross out "IP 25" and mark
f
the box "IP 24". Use a ballpoint pen to do this.
24
18 Nm
f Fit water plugs with gaskets to seal the concealed connec-
f
tions. All taps obtained as accessories are supplied with
plugs and gaskets as standard. For pressure-tested taps
other than those recommended by us, plugs and gaskets can
be ordered as accessories.
19
5 Nm
www.stiebel-eltron.com