Fume Stack Maintenance; Fume Coil Maintenance - Palazzetti TERMOPALEX HWT Notice D'utilisation Et D'entretien

Masquer les pouces Voir aussi pour TERMOPALEX HWT:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

5.3 Fume stack maintenance

Incrustations inside the fume stack compromise
optimal draft. When they reach a thickness of
5-6 mm, high temperatures and sparks may
cause them to catch fire with readily imagined
consequences for the flue and the home.
It is therefore advisable to clean the
flue at least once a year, or every 4000
kg of wood burnt (as specified in the
product standard). Contact specialised
personnel.

5.4 Fume coil maintenance

It is also advisable to clean the heat
exchange coils and turbulators at
least once a year, or every 4000 kg of
wood burnt (as specified in the prod-
uct
standard).
personnel.
Removing the refractory material
Remove the upper locking bracket that aligns
the rear wall with the two corner pieces (A - Fig.
5.4a).
Remove the upper locking brackets that align the
side walls with the rear wall (B - Fig. 5.4a).
Remove the rear wall (Fig. 5.4b).
Remove the two side walls (Fig. 5.4c).
Remove the two corner walls (Fig. 5.4c).
B
A
30
Contact
specialised
B
Fig. 5.4a
Fig. 5.4b
Fig. 5.4c
Fig. 5.4d
004778230 - 15/04/2020

Publicité

Table des Matières
loading

Table des Matières