OPERATION
Cleaning, care and maintenance
5.
Cleaning, care and maintenance
f Have the electrical safety of the appliance and the function
f
of the safety assembly regularly checked by a qualified
contractor.
f The signal anode must be replaced by the qualified contrac-
f
tor as soon as the SERVICE ANODE indicator illuminates (see
chapter "Maintenance / Replacing the signal anode").
f Never use abrasive or corrosive cleaning agents. A damp
f
cloth is sufficient for cleaning the appliance.
Scaling
f Almost every type of water will deposit lime at high temper-
f
atures. This settles inside the appliance and affects both the
performance and service life. The heating elements must
therefore be descaled from time to time. A qualified contrac-
tor who knows the local water quality will tell you when the
next service is due.
f Check the taps/valves regularly. You can remove limescale
f
deposits at the spouts using commercially available descaling
agents.
f Regularly activate the safety valve to prevent it from becom-
f
ing blocked, e.g. by limescale deposits.
6.
Troubleshooting
Problem
Cause
The water does not heat
There is no power.
up.
The flow rate is low.
The aerator in the valve
or the shower head is
scaled up or contami-
nated.
SERVICE ANODE indicator
The signal anode needs
illuminates.
replacing.
If you cannot remedy the fault, notify your qualified contractor.
To facilitate and speed up your enquiry, please provide the serial
number from the type plate (000000-0000-000000):
22
| SH S
Remedy
Check the fuses/MCBs in
your fuse box.
Clean and/or descale the
aerator or shower head.
Notify your qualified
contractor.
Nr.: 000000-0000-000000