Manual regeneration
At any time, it is possible to trigger the regeneration of the softener, via the long press (5 seconds)
on the oK key.
If this is done for a test purpose, it is possible to manually go from one step to the next by briefly
pressing the oK key.
salt alarm acknowledgement
When no salt is left in the tank, the device displays the alternate words sALT and cHecK.
Once the salt refill is done, you may just wait for the next regeneration to let this alarm disappear. It
is recommended though to acknowledge immediately the alarm, following these steps:
•
Proceed with a long press (5 seconds) on the M key
•
Then briefly press this M key to go through the menus until the display shows this one:
•
Press once on
ê
Press oK to confirm
•
Press M during 5 seconds to quit the menu: the alarm shall disappear
•
Power cut
In case of a power cut during a regeneration, this process restarts at the beginning of the ongoing
step. In case of a power cut during service, the softener will restart also in service.
stand-by mode
It is possible to prevent the softener from going through a regeneration, automatic or manual. This
might be useful, for example, while you are waiting for the intervention of a technician in case of
technical problem. Therefore:
•
Proceed with a long press (5 seconds) on the M key
•
Then briefly press this M key to go through the menus until the display shows this one:
•
Press once on
ê
•
Press oK to confirm
The display shows then the message sTd-BY alternating with the softener autonomy value.
To cancel this function, you just have to come back to this sTANd-BY menu and turn the lower line
into oFF.
Accessed by the code 23, then the browsing works in the same way as the regular setting mode.
The intervention on the advanced setting shall be done by a trained professional. Any mistake can
disturb the work of the device and is under its author's responsibility.
30
Manual soFTeNer A27-A6X code P0011144 - Rev 7 - 11/04/2018
cHecK / sALT (alternate)
on
or
key to make oFF appear on the lower line
é
sTd-BY
Off
or
key to make oN displayed on the lower line
é
AdVANced seTTiNG