step n°
display
PAssW ?
Enter the password to go through the advanced set-
0
00
ting.
Enable / disable the proportional regeneration (the
ProP r
1
scope of delivery sheet specifies the integration of
on
this function in the softener).
Modify the softening capacity of the device, which has
cAPA
2
been automatically set once the resin volume was se-
80
lected (step 3 of regular setting).
Adjust the water consumption per full regeneration.
coNsu
3
Only for devices with the salt level follow-up by smart-
71
phone app.
Adjust the salt consumption per full regeneration.
sALT
4
Only for devices with the salt level follow-up by smart-
2000
phone app.
VoL oK
Volume of softened water (read only info). Here: 856
5
8 56
liters.
PeAKFL
Peak flow recorded since the last regeneration (read
6
10 68
only info). Here: 1068 liters per hour.
N reGe
Number of regenerations done since the commissioning.
7
48
May be reset.
cHLor
8
Enable / disable the chlorination function
Off
ALArMe
9
Salt lack alarm enabled / disabled
Off
sAFe L
Safe level value = remaining capacity value which trig-
10
2 50
gers the regeneration once reached.
reGe T
11
Time of regeneration start.
2:00
Press
Water network pressure. To be set for proportional re-
12
4
generation purpose.
Frequency of the full regenerations (to prevent from
FuL rG
loss of capacity occurring with time), for the softeners
13
5
with proportional regeneration function. Here: one full
regeneration every 5 regenerations.
Setting of each regeneration step durations.
The followings step durations can be adjusted (one
sTePs
14
submenu for each): Backwash (BACKW) ; aspiration
(ASPI) ; fast rinse (FAST) ; brine preparation (propor.
regen.) (BRINE) ; tank refill (propor. regen.) (REFILL)
Forced
Turn ON or OFF the automatic forced regeneration after
15
NoNe
a long time without water consumption
reseT
16
Reset back on initial factory settings
oFF
Purpose
Manual soFTeNer A27-A6X code P0011144 - Rev 7 - 11/04/2018
Action
êé to change
oK to confirm
çM to cancel
ê to turn on / off
oK to confirm
çM to cancel
êé to change
oK to confirm
çM to cancel
êé to change
oK to confirm
çM to cancel
êé to change
oK to confirm
çM to cancel
çM to go to next step
çM to go to next step
êé to change
oK to confirm
çM to cancel
êé to change
oK to confirm
çM to cancel
êé to change
oK to confirm
çM to cancel
êé to change
oK to confirm
çM to cancel
êé to change
oK to confirm
çM to cancel
êé to change
oK to confirm
çM to cancel
êé to change
oK to confirm
çM to cancel
oK to enter the menu,
otherwise çM then
êé to change
oK to confirm
çM to cancel
êé to activate
oK to confirm
çM to cancel
êé to turn ON
oK to confirm (twice)
çM to cancel
31