The numbers in bold refer to the marks in chapter INSTALLATION - OVERVIEW
step
Tighten the hydraulic block
check the network pressure
check the power outlet
insert a tap for non-softened water (14)
Install the pre-filter (7)
install the by-pass (12)
Note: the shown by-pass is wall-mounted single
block brass by-pass
24
Manual soFTeNer A27-A6X code P0011144 - Rev 7 - 11/04/2018
iNsTALLATioN Procedure
directions
The preliminary tightening of the hydraulic block
upon the vessel is crucial because untightening
during transportation may have occurred.
The pressure shall be between 1.5 et 7 bars.
Above 5 bars, install a pressure reducer.
Check that there is a power outlet of 230 V at less
than 1.20 meters.
In case you need to keep raw water (for example
for gardening, etc.)
Place and connect the filter upstream from the
softener.
Comply with the water flow direction as shown
on the filter head.
Fix the filter head on the wall with the bracket,
without tightening too much the screws on the
filter head.
Install the bypass on the pipe complying with the
water flow direction.
Turn the bypass tap into the softener by-pass
position.