Condair 505 Mode D'emploi page 20

Masquer les pouces Voir aussi pour 505:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles


Maintenance and cleaning
.1
Cleaning intervals
.2
Dismantling and assembly
505
20
Regular checks and periodic maintenance are indispensable prerequisites
for hygienic operation:
– Regular checks
Once a week you should carry out a regular check that includes the fol­
lowing steps:
– cleaning of the water reservoir.
– checking all components being in contact with water (i.e. filter, suction
piece, whirl disk, guiding disk, atomizer ring, etc.).
– Periodic maintenance
The maintenance interval depends on the operating conditions. We rec­
ommend the following intervals:
– high ratio of dust and/or hard water:
– medium ratio of dust and/or normal water:
– low ratio of dust and/or demineralized water:
Note: please refer to chapters 6.2 and 6.3 for detailed descriptions of the
dismantling, assembly and cleaning procedures required by particular com­
ponents.
Dismantling
• Disconnect the unit from the mains (pull the plug out of the socket)
• Remove the atomizer unit and the support disk.
• Remove the aerosol discharge hood from the atomizer unit.
• Firmly hold the whirl disk while turning the suction piece anticlockwise
until it comes off.
• Remove the whirl disk and the guiding disk.
• Carefully dismantle the segments of the atomizer ring.
Caution! Cleaning and replacement of defective parts do not require further
dismantling which is inadmissible and may void the warranty.
Assembly
Proceed in the reverse order of the dismantling procedure to reassemble
the unit.