Power
• the supply lines of the electric energy should meet the requirements of power
power supply
• check that the power line:
Automati c
safety switches
• protect the upstream cabinets with omnipolar circuit breakers with suitable
• instruct the operator on the positi on of the switches to be reached quickly in
Before
connecti ng
• consult the wiring diagrams annexed to the counter
• ensure that the rati ng plate data matches the characteristi cs of the electrical
• check that power supply voltage is the one reported on the rati ng plate
• remove all metallic objects worn: rings, watches, bracelets, earrings, etc.
• proceed with wiring
i
If the electrical supply is interrupted, the electrical equipment of the shop will not restart,
triggering the overload protecti on devices; modify the system to diff erenti ate the start-up of
the various devices.
15. Control and adjustment of the temperature
the cooling temperature is controlled by means of:
digital solar thermometer (Fig.14); the electronic controller (opti onal) (Fig.13)
i
To change the controller programming, call the manufacturer.
16. Cabinet loading
ATTENTION! Opening the doors. Tilti ng of the cabinet. Injuries, wounds.
DO NOT open all the doors at the same ti me Fig.21
Before loading the goods, wash and disinfect the cabinet as indicated in chapter 21.
max allowed capacity evenly distributed of tray: 350 kg/m
max allowed capacity evenly distributed of shelves: 160 kg/m
05060184 01 25-11-2019
consumpti on of the cabinet chap.9.
- has wires with suitable cross secti on
- is protected against over-current, overload and dispersions toward earth in
accordance with the rules in force
- for power lines longer than 4-5 m use cables with suitable cross-secti on.
i
The replacement of the damaged power cord is reserved to the manu-
facturer or a body authorised by the same.
DANGER! Live parts. Short circuit. Electrocuti on
The automati c circuit breakers must be such that they do not open the
circuit on the neutral, without simultaneously opening on the phases
and, in any case, must allow complete disconnecti on in conditi ons of
category III overvoltage
characteristi cs that will also functi on as master switches to secti on off the line
case of EMERGENCY
DANGER! Live parts. Short circuit. Electrocuti on
Check that the att achments of the lighti ng systems (fl oors, roof, ceil-
ing) are properly inserted and locked into their housings to avoid
disconnecti ons during cleaning and maintenance operati ons, that may
cause harmful electric shocks.