Identification - Rating Plate - Arneg Osaka 3P Manuel D'installation Et De Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 84
O s a k a 3 P
Vertical multi-deck & Semi-vertical
English
The performance of these refrigerated cabinets was determined through tests conducted in com-
pliance with the standard EN ISO 23953 - IEC/EN 60335-2-89 at the environmental conditions of
climate class 3 (25°C , 60% R.H.) with safety test at 32°C +/-2°C see table:
Climatic Class of the
testing chamber
0
1
2
3
4
6
5
7
8
The weight of water vapour in dry air is one of the main points that affect the performance and
power consumption of the cabinets.
Declaration of
A copy of the conformity statement is annexed to the counter.
If the original copy of the Declaration of Conformity supplied with the unit is
conformity
lost, download a copy by filling out the form found in the footer of the home
page of the website www.arneg.it under "EU compliance"

9. Identification - Rating Plate

The serial plate containing all technical specifications (Fig.2) is affixed to the side of the counter:
N °
1
place/name of the manufacturer;
2
name and length of the counter
3
code of the counter
4
serial number of the counter
5
supply voltage
operating electrical power absorbed in the defrosting phase
6
(armoured heaters+hot wires+ fans+lighting)
7
usable display surface
8
type of refrigerant fluid used by the system to operate
9
environmental climatic class and temperature of reference
10
number of the job order based on which the counter has been manufactured
11
number of purchase order based on which the counter has been put in production
12
year of manufacture of the counter
13
EAC marking
14
operation class
weight of refrigerant gas loaded in every system
15
(only for counters with a built-in motor)
16
heating capacity
17
lighting power (where included)
18
class of protection against humidity
19
QR code
20
operating current consumption
operating electrical power absorbed in the refrigeration phase
21
(fans+hot wires+lighting)
22
Power supply frequency
i
For assistance, give the manufacturer the following information:
- the product name (2); the serial number (4); the job order number (16)
UNDER NO CIRCUMSTANCES remove the serial plate
40
Temperature
dry bulb
Humidity
° C
20
16
22
25
3 0
27
40
3 5
23.9
Relative
Dew
p o i n t
%
° C
50
9.3
80
12. 6
65
15. 2
60
16. 7
55
20. 0
7 0
21. 1
40
23.9
7 5
3 0. 0
55
14. 3
N a me
Weight of water
vapour in dry air
g/kg
7 . 3
9.1
10. 8
12. 0
14. 8
15. 8
18. 8
27 . 3
10. 2
05060184 01 25-11-2019