Glass Doors; Vertical Glass Doors, High Efficiency Models - Air System Technology; Maintenance And Cleaning - Arneg Osaka 3P Manuel D'installation Et De Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 84
ATTENTION! Accidental breakage of bulbs. Injury. Contaminati on of the goods.
- wear PPE
- cut off power supply to the cabinet
- remove all goods
- clean the cabinet as indicated in secti on 21.4
- remove any trace of glass from the goods
- replace the bulbs with identi cal ones
- reload the cabinet with goods cleaned thoroughly
- restore electrical power supply.

19. Glass doors

Operati on
• the door closes by itself for angles of less than 60°
• for angles greater than 60° the door locks to facilitate loading and cleaning
Fig.21
• to close, simply accompany the door in closing
i
It is the Customer's responsibility to inform consumers with suitable means of communica-
ti on about correct use of the doors.
20. Verti cal glass doors, high effi ciency models - Air System Technology
Osaka 3P verti cal glass door models can be supplied in the Arneg Air System version.
Applicati ons
• only on verti cal furniture closed with evaporator in the tank
• it can be connected to the line of the store's air conditi oning system
Benefi ts
• evaporati on temperature increased by 7°C
• total energy consumpti on reduced by 37%
(with respect to a
standard model of
• product temperatures always within a 2°C range in any conditi on of use (M0,
the same type)
• no need for defrosti ng
• no product temperature fl uctuati on
• no risk of blocking of the evaporator due to ice as the water is produced directly
• no need for defrost probes
• no need for defrost resistors.
Air system technology cannot be applied:
- to models already present in the store!
- to semi-verti cal models

21. Maintenance and cleaning

DANGER! Live parts. Electrocuti on.
REMOVE THE ELECTRIC POWER SUPPLY BEFORE ANY OPERATION!
DO NOT wet, spray water or clean directly the electrical parts of the cabinet (fans, inte-
rior lighti ng, electrical cables etc.)
DO NOT touch the counter with wet or damp hands or feet
05060184 01 25-11-2019
operati ons
See chap.4.4
it only achieves the best performance if connected to a specifi c condens-
ing unit or to a dedicated control unit
M1, M2)
in the fl uid phase
O s a k a 3 P
Verti cal multi -deck & Semi-verti cal
English
47