C a b i n e t
• poor room conditi ons
temperature
is too high or
• output air temperature is
too low
outside the specifi ed range
• the cabinet is defrosti ng.
• the capacitor or the evaporator
are freezing.
• the capacitor or the evaporator
are obstructed or dirty.
• the load is not distributed even-
ly
Water leaks,
• cabinet drains are obstructed or
b a d s me l l
damaged
• water collecti on tray is sealed
incorrectly
• water collecti on tray overfl ows • check wiring of evaporati on heater
• insuffi cient joints between cabi-
nets in channel or joints not
sealed correctly
Frost or ice
in the cabinet
• fans do not work in the evapo-
rator
• heati ng elements broken
• Sdef probe detached
• air currents that alter the circu-
lati on of refrigerated air
i
in all cases not described or where it is not possible to solve the problem by following these
directi ons call the nearest authorised aft er-sales centre.
27 . Assembly/disassembly instructi ons
DANGER! Live parts. Electrocuti on.
REMOVE THE ELECTRIC POWER SUPPLY BEFORE ANY OPERATION!
Follow chapters 1-2-3-4-5
Protect the hands with work gloves
05060184 01 25-11-2019
O s a k a 3 P
Verti cal multi -deck & Semi-verti cal
• check the positi on of the cabinet inside the
store chap.12
• check the operati on of evaporator fan
• check wiring and input voltage
• the fans are installed reversely; check and re-
store the air fl ow directi on
• check that fan plenum is suffi cient and not
obstructed
• check the intake pressure that should comply
with rated specifi cati ons
• check defrosti ng parameters
• check that the sucti on line is not obstructed
• proceed with cleaning
• load the goods in an orderly fashion (Fig.15)
• free the drain
• repair or replace the drains
• seal it properly
• check the operati on of evaporati on heater
• install and seal the joints
• check electrical connecti ons
• check the venti lati on inside the store
English