Before
connecti ng
• consult the wiring diagrams annexed to the cabinet
• ensure that the rati ng plate data matches the characteristi cs of the electrical
• check that power supply voltage is the one reported on the rati ng plate
• remove all metallic objects worn: rings, watches, bracelets, earrings, etc.
• proceed with wiring
i
If the electrical supply is interrupted, the electrical equipment of the shop will not restart,
triggering the overload protecti on devices; modify the system to diff erenti ate the start-up of
the various devices.
15. Positi on of probes (Fig.27)
The probes are already assembled in the cabinet and are:
Sout Air inlet control probe
Sdef Defrost end thermal switch control probe
Sin
Sucti on air control probe
Ster Mechanical/solar thermometer probe
Temperature probe: NTC IP67 L=4000 code 04510153.
The Sout - Sin probes must be blocked with terminals and must not be insulated.
The probe Sdef should be secured in contact with the fi ns of the evaporator between the 3rd and the
4th tube (never close to the fan) using a bulb holder stainless steel spring code 02230021.
16. Control and adjustment of the temperature
the cooling temperature is controlled by means of:
digital solar thermometer (Fig.14); the electronic controller (opti onal) (Fig.13)
i
To modify the programming of the controller, call the manufacturer.
17. Loading the cabinet
ATTENTION! Opening the doors. Tilti ng of the cabinet. Injuries, wounds.
Do NOT open all the doors at the same ti me Fig.20
max allowed capacity evenly distributed of tray: 350 kg/m
max allowed capacity evenly distributed of shelves: 160 kg/m
• load the unit one door at a ti me
Remedy
• arrange the products in order and evenly (Fig.15)
• leave a 30 mm clearance between the goods and the top shelf (Fig.16)
• introduce products already cooled at the required storage temperature
• load the cabinet so that the goods from a longer ti me are sold before the
• on bent shelves, always use retainers.
05060185 00 19-06-2019
DANGER! Live parts. Short circuit. Electrocuti on
Check that the att achments of the lighti ng systems (fl oors, roof, ceil-
ing) are properly inserted and locked into their housings to avoid
disconnecti ons during cleaning and maintenance operati ons, that may
cause harmful electric shocks.
system to which the cabinet must be att ached
block the door in the open positi on unti l loading has been completed
DO NOT open and close conti nuously
newly received goods (stock rotati on)
(Fig.15)
2
(Fig.15) (Fig.17)
2
Santi ago 2
English