MAINTENANCE
Maintenance operations must be performed by an authorised technical assistance centre.
Before performing any maintenance operation, take the following precautions:
• Ensure that all appliance parts are cold.
• Make sure that the ashes are completely extinguished.
• Use personal protective equipment provided for by Directive 89/391/EEC.
• Make sure that the general line switch is turned off.
• Make sure that the power supply cannot be accidentally reactivated. Remove the plug from the
wall socket.
• Always use appropriate equipment for maintenance.
• Once maintenance or repair operations have been completed, before putting the appliance back
into service, reinstall all the safety guards and reactivate all the safety devices.
9.1
Ordinary maintenance cleaning program
9.1.1 Ordinary cleaning (User)
Burn pot (Fig. 48)
Ash drawer/compartment (Fig. 49)
Glass (Fig. 50)
Smoke collector
1
9.1.2 Ordinary maintenance (certified technical service centre)
Door and burn pot seals
Flue gas T-pipe
Smoke collector
2
Auger
Smoke system
Door block springs
(*)
At least once a year or every 4000 kg of pellets burned.
74
EVERY TIME THE APPLIANCE
IS TURNED ON
X
EVERY WEEK
X
X
X
1 YEAR (*)
X
X
X
X
X
X
004778890 - 12/11/2021