7.3 Assembly diagram
1) For correct installation, all the joints of the
flue gas ducting between the fireplace and
the flue must be sealed.
2) Lining in eco-friendly ceramic fibre or rock
wool with external aluminium foil.
3) Rear external air intake, ensure a minimum
distance of 5 cm between cladding and com-
bustion air intake pipe.
4) Provide an opening of a suitable size for clean-
ing and servicing the room fan (for model
AC78 only).
5) The lining must be made of fireproof material.
6) Min distance. 1 cm between cladding and
fireplace stove.
7) Protect any wooden parts with fireproof
material.
8) Counter-hood and fireproof load-bearing
structure.
9) Pellet loading system. See the instructions
supplied with the kit for installation.
10) UNI standards require the installation of a
heat recovery grille as close as possible to the
ceiling.
68
A
B
C
Fig. 33
10
9
8
7
6
5
4
7.3.1 Insertion of room sensor
The sensor must be installed near the side or
front suction holes of the cladding base.
Glue the probe wire in correspondence with the
air intakes
1
2
3
4
Fig. 34
Fig. 35