Characteristics of the premises
A door 90 cm wide is required to enter the machine, the tubs having been previously taken out.
The machine must be installed in well ventilated premises (particularly in the case of
gas heating) with correct lighting and ambient temperature not in excess of -10 to +
40°C (temperature limit for the electronic frequency variator of the drive motor).
Sufficient space must be allowed around the machine to ensure its satisfactory
operation:
Minimum 5 to 10 cm to the rear for ventilation (ideally 60 cm to facilitate
maintenance).
60 to 80 cm on each side for servicing and maintenance.
Sufficient space to the front must be left free to allow the operator to work correctly
and safely.
The levelling must be carried out correctly on a hard and stable floor, capable of
withstanding the relatively considerable weight of the machine (700 to 1300 kg over
2 to 3.4 m²). A minimum floor resistance of 500 kg/mm is required for setting such a
machine in place.
Connections
Electrical connection: ensure that the characteristics of the electricity supply
correspond to those of your machine, indicated on the identification plate on its left
panel, and that the section of the cable or other accessories of the line can provide
the required power.
To connect the machine, remove the left panel and connect each of the wires of the feed
cable L1, L2, L3, and Neutral at the terminals of the general switch and the earth wire on the
earth terminal. It must be perfectly correctly earthed in order to guarantee user safety
and satisfactory functioning.
The electrical connection on the site must comply with currently applicable regulations, and
it is obligatory to insert a magneto-thermal circuit breaker and a differential (not supplied)
between the connection and the mains. The sensitivity of the differential must be 300mA. A
higher degree of sensitivity, 30 mA for example, as habitually used in domestic appliances,
may give rise to malfunctioning of the machine.
Section of the input electricity cable (mm²):
TYPE
2000
Heating
Electric
230V-1P-T
230V-3P-T
4*25
400V-3P-N+T
5*10
2000
Gas/steam
-
4*2.5
5*2.5
DOC MACHINE Ø50.0-EN by PS on 19/06/2015,
2600
2600
Electric
Gas/steam
-
4*35
4*2.5
5*16
5*2.5
3300
3300
Electric
Gas/steam
-
4*35
4*2.5
5*25
5*2.5
Page 12 of 33