Technical Data; Gas Heating - grandimpianti C 200/51 Instructions Pour L'installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
TYPE
Usable length (mm)
Ø Cylinder (mm)
HEATING ELECTRIC
Heating power (kw)
Motor power (kw)
E=Voltage

GAS HEATING

Calorific flow (kw)
Natural gas flow (20 mbar)
m3/hour
LPG gas flow (37 mbar) kg/hour
G= Ø gas input (mm)
Required electrical power
E=Voltage
STEAM HEATING
Steam pressure (bar)
Hourly consumption kg/h
Motor horse power (kw)
SI= Ø steam input
SO= Ø steam output
E=Voltage
Steam Exhaust - Number
Ø outlet (mm)
Ø flue (mm)
Power extraction (m³/hour)
Heating surface (m²)
Hourly productivity (kg/hour)
Water evaporation (l/hour)
Noise level (Db)
Floor space with trays (mm)
Floor space without trays (mm)
Shipping dimensions
Net weight (kg)
Gross weight (kg)

0. TECHNICAL DATA

Ø50/2000
2000
500
31,5
0,62
400/50/3+N+T-50A
240/50/3+T-100A
40
4,2
3,1
22
0,87
400/50/3+N+T-2A
240/50/3+T-4A
10
50
0,62
3/4"
1/2"
400/50/3+N+T-2A
240/50/3+T-2A
1 or 2
153
153 or 2*153 in gas
600 or 1200
3,14
50/70
35-49 l/h
60
2810*836*1189
2810*956*1189
3010*1150*1500
925
974
DOC MACHINE Ø50.0-EN by PS on 19/06/2015,
Ø50/2600
2600
500
40,5
0,87
400/50/3+N+T-63A
240/50/3+T-125A
55
5,8
4,3
22
0,87
400/50/3+N+T-2A
240/50/3+T-4A
10
67
0,87
3/4"
1/2"
400/50/3+N+T-2A
240/50/3+T-4A
2
153
2*153
1200
4,082
60/80
42-56 l/h
65
3410*836*1189
3410*956*1189
3610*1150*1500
1200
1270
Ø50/3300
3300
500
54
0,87
400/50/3+N+T-100A
240/50/3+T-160A
69
7,3
5,6
22
0,87
400/50/3+N+T-2A
240/50/3+T-4A
10
85
0,87
3/4"
1/2"
400/50/3+N+T-2A
240/50/3+T-4A
2
153
2*153
1200
5,181
80/120
56-84 l/h
65
4110*836*1189
4110*956*1189
4310*1150*1500
1436
1475
Page 4 of 33

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

C 260/51C 330/51

Table des Matières