Technical Data - Migatronic Rally MIG 161i Guide De L'utilisateur

Masquer les pouces Voir aussi pour Rally MIG 161i:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15

Technical data

Power source
Mains voltage ±15% (50Hz-60Hz), V
Fuse, A
Mains current effective, A
Mains current max., A
Power (100%), kVA
Power max., kVA
Open circuit power, W
Efficiency
Power faktor
Current range, A
Duty cycle, 100% at 20°C, A
Duty cycle, 60% at 20°C, A
Duty cycle, 40% at 20°C, A
Duty cycle, 100% at 40°C, A/V
Duty cycle, 60% at 40°C, A/V
Duty cycle, max. at 40°C, A/%/V
Open circuit voltage, V
1)
Sphere of application
Protection class
2)
Norm
Dimensions (HxWxL), mm
Weight, kg
90
80
70
60
50
40
30
20
10
0
0
40
1) S This machine meets the demand made for machines which are to operate in areas with increased hazard of electric chocks
2) Equipment marked IP23S is designed for indoor and outdoor applications
10
RALLYMIG 161i
230
16
13.0
22.9
2.4
4.4
30
0.8
0.99
20-160
135
145
160
100/24.0
115/24.6
160/25/26.4
90
S/CE
IP23S
EN/IEC60974-1.
EN/IEC60974-5.
EN/IEC60974-10
370x230x450
13
Static Characteristic
80
120
160
EC DECLARATION OF CONFORMITY
hereby declare that our machine as stated below
Type: RALLYMIG 161i
As of week 32, 2013
conforms to directives 2006/95/EC
European standards:
Issued in Fjerritslev on 15 August 2013.
Anders Hjarnø Jørgensen
RallyMig 161i
MIG Load line
MMA Load line
I2 [A]
MIGATRONIC A/S
Aggersundvej 33
9690 Fjerritslev
Denmark
2004/108/EC
2011/65/EU
EN/IEC60974-1
EN/IEC60974-5
EN/IEC60974-10 (Class A)
CEO

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rally mig 161i

Table des Matières