Problem
No coating material
emerges from the
nozzle
Coating material
drips from the
nozzle
Atomisation too
coarse
Spray jet pulsates
Coating material
causes "paint tears"
Too much fog of
coating material
(Overspray)
Device does not
function
Cause
Nozzle clogged
Material volume setting
turned too far to the left (-)
No pressure build-up in
container
Container empty
Feed tube loose
Feed tube clogged
Ventilating bore (Fig.12, C)
clogged
Coating material assembly
at air cap, nozzle or needle
Nozzle loose
Nozzle seal worn
Nozzle worn
Material volume too large
Material volume adjusting
screw turned too far to the
right (+)
Nozzle contaminated
Viscosity of coating material
too high
Too little pressure build-up
in container
Air filter heavily soiled
Coating material in
container running out
Nozzle seal worn
Air filter heavily soiled
Too much coating material
applied
Viscosity of coating material
too low
Distance to the object too
large
Too much coating material
applied
Device overheated
Remedy
Clean
Turn to the right (+)
Tighten container
Refill
Insert
Clean
Clean
Clean
Union nut tighten
Change
Change
Turn material volume
adjusting screw to the
left (-)
Clean
Dilute further
Tighten container
Change
Refill
Replace
Change
Turn material volume
adjusting screw to the left (-)
Reduce distance
Turn material volume
adjusting screw to the left (-)
Unplug the power plug,
let the device cool down
approx. 30 minutes, do not
bend the hose, check the
air filter, do not cover the
intake slots