GB
Problem
Paint in the
ventilating hose
Poor covering
capacity on the wall
Warning
If the supply cord of this appliance is
damaged, it must only be replaced
by a repair shop appointed by the
manufacturer, because special purpose
tools are required.
Warning: Do not connect the blue
or brown wire to the earth
terminal of the plug! The
wires in this mains lead are
coloured in accordance with
the following code:
blue = neutral
As the colours of the wires in the mains lead of this appliance may not correspond with
the coloured markings identifiying the terminals in your plug, proceed as follows:
•
Should the moulded plug have to be replaced, never re-use the defective plug or
attempt to plug it into a different 13 A socket. This could result in an electric shock.
•
Should it be necessary to exchange the fuse in the plug only use fuses approved by
ASTA in accordance with BS 1362. 5 Amp fuses may be used.
•
To ensure that the fuse and fuse carrier are correctly mounted please observe the
provided markings or colour coding in the plug.
•
After changing the fuse, always make sure that the fuse carrier is correctly inserted.
With out the fuse carrier, it is not permissible to use the plug.
•
The correct fuses and fuse carriers are available from your local electrical supplies
stockist.
22
Cause
•
Diaphragm soiled
•
Diaphragm defective
•
Spray material is too cold
•
Highly absorbent surface
or paint with poor covering
capacity
•
Distance too large
brown = live
WallPerfect W 665
Remedy
Clean the diaphragm
➞
Replace the diaphragm
➞
Heat spray material
➞
maximum 40°C)
Cross spray (Fig. 13)
➞
Closer to the object
➞
(to