Operating instructions SATAjet 5000 B RP/HVLP (DIGITAL)
9.4. Replacing the Air Piston, Air Piston Spring
and Air Micrometer Steps:
• Disconnect the spray gun from the compressed air circuit!
This must be exchanged if air is leaking from the air nozzle or the air
micrometer while the trigger is not pulled. After disassembly, grease air
micrometer shell with SATA gun lubricant (item no. 48173), use with air
piston and tighten locking screw using original SATA combination tool with
max. 1 Nm. [10-1]. After installation, set material throughput according to
chapter 7.2.
• Check if the locking screw has been firmly tightened! The air microm-
eter could shoot out from the spray gun uncontrolled!
9.5. Replacing the Sealing (air side)
• Disconnect the spray gun from the compressed air circuit!
Steps: [9-1], [9-2], [10-1], [10-2], [10-3], [10-4] and [10-5]
Replacing the self-tensioning sealing [10-5] is required when air leaks
from under the trigger.
1. After disassembly, please check air piston rod [10-4] and clean it, if
required. If damaged (e.g. if scratched or bent), replace it and grease
with SATA high performance spray gun grease (Art. No. 48173) and
insert. Please observe correct order of installation!
2. Also grease air micrometer shell, insert with air piston and tighten
locking screw using original SATA combination tool with max. 1 Nm.
After installation, please adjust material flow according to chapter 7.2.
• Check if the locking screw has been firmly tightened! The air microm-
eter could shoot out from the spray gun uncontrolled!
Danger!
Danger!
Danger!
Danger!
[10-1], [10-2] and [10-3]
US
509