Operating instructions SATAjet 5000 B RP/HVLP (DIGITAL)
• Drillings should be cleaned with SATA cleaning brushes or SATA nozzle
cleaning needles only. The use of other tools may cause damage or
may affect the spray pattern. Recommended accessory: cleaning kit
Art. No. 64030.
• Exclusively use spray gun washing machines recommended by SATA!
Please observe the operating instructions!
• The air passages have to be put under pressure with clean compressed
air during the entire cleaning process!
• Nozzle head has to point downwards!
• Remove the spray gun from the gun washing machine imme-
diately after the cleaning process!*,**
• Never use ultrasonic cleaning devices - leads to damage of noz-
zle set and gun surface!**
• After cleaning, the spray gun, the material passages, the air
cap including thread as well as the gravity flow cup have to
be blown dry with clean compressed air!*
* otherwise risk of corrosion
** otherwise damage of the electronic components of DIGITAL
spray guns
• Check spray pattern after cleaning the nozzle set!
• Further cleaning tips can be found at www.sata.com/TV.
9.

Maintenance

• Prior to maintenance, disconnect the spray gun from the compressed
air circuit!
• Disassemble and install components very carefully! Exclusively use
included special tools!
Danger! Notice!
Information!
Danger! Notice!
US